What to look at on the radiator before you take the key
- The valve’s position The bleed valve is in the radiator’s upper corner. If the radiator is cool right at the top, there is most likely air there.
- The valve head A square stem means a bleed key, a slot means a flat screwdriver. Get the tool in advance, not at the moment the radiator is already cold.
- Paint on the valve If the valve is painted over, carefully clean the paint from around the head. If it still does not turn, do not force it: a broken valve is replaced by a plumber.
- The thermostatic head’s number If the thermostatic head is turned to zero or to the frost symbol, the radiator can be cold without any air at all. IMI Heimeier states that for heads with a zero position the valve opens only at about 0 °C.
- The pressure gauge in a private house Write down what the boiler’s pressure gauge shows. After bleeding you will have something to compare with.
Bleeding as Stelrad recommends
- A cloth under the valve Hold a folded cloth or a small container under the valve: after the air comes water, and it can be hot and dark.
- A quarter to half a turn Turn anticlockwise slowly. Stelrad advises never opening the valve fully.
- Close when water comes When a steady trickle replaces the hiss, close the valve without extra force.
In a two-storey private house Stelrad advises starting with the radiators on the lower floor and only then going upstairs.
Why air appears on the upper floor first
The Grīvas iela estate, whose construction began in 1958–1960, has six-storey blocks with artists' studios in the attic. The highest radiators there are under the roof, and air in the system rises straight to the highest point. The same happens in Iļģuciems’s nine-storey series 602 blocks and in the 12-storey buildings of the Czech design, where the riser is long.
Air often appears in autumn, when the riser is refilled after the summer work. The flat’s valve lets out only the air that is in your radiator. If several radiators on one riser are cold, or the pipe that comes to the radiator already is, report it to your building manager; the check of valves and supply pipes is described on the page radiator repair.
The radiator is cool but there is no air
If the valve hisses only for a moment or water comes at once, air is not the fault. Two places to check:
- The thermostatic head: the setting range of the IMI Heimeier K head is 6–28 °C with a frost-protection function. At the frost symbol the radiator heats only enough to keep the room from freezing.
- The valve setting: under the head a Danfoss RA-N valve can have a step from 1 to 7 set, and a lower number limits the flow. The manufacturer states that in one-pipe systems the setting must be N, fully open.
In an apartment building the valve and the radiator are part of the building’s system, so do not change the setting yourself: ask your building manager.
In a private house after bleeding: topping up
Together with the air, water also leaves the closed loop, so the pressure gauge shows less than before the work. The filling tap is usually at the boiler: it is either a built-in valve or a short hose between the water supply and the heating loop. Open it slowly and close it when the reading reaches the required value; disconnect the hose afterwards. The expansion vessel’s pre-charge pressure is usually written on the vessel’s label.
Flamco (an expansion vessel manufacturer): after the system has been heated up, when the water has cooled to about 50 °C, the system is topped up to 0.3 bar above the expansion vessel’s pre-charge pressure. Checked 16.11.2026.
When bleeding should be left to a plumber
Stelrad writes: if radiators have to be bled often, there is another cause, and a specialist should be found. In a private house air often comes with new water that is added because something leaks somewhere; if the lower part of a radiator stays cold, heating system flushing helps. In an apartment building, repeated air on an upper floor is a reason to write to the building manager.
The plumber’s call-out and inspection is from €40. There is no single price for releasing air from radiators. It depends on how many radiators have to be bled, whether water has to be added and the pressure raised in a private house system, and whether the air returns and the source has to be found.
Sources
- Open slowly, a quarter to half a turn, never fully; start on the lower floor; if bleeding is needed often, find a specialist checked 16 November 2026
- At about 50 °C top up to 0.3 bar above the expansion vessel’s pre-charge pressure checked 16 November 2026
- K head: settings 6–28 °C with a frost-protection function; for models with a zero position the valve opens at about 0 °C checked 16 November 2026
- RA-N pre-setting 1–7, N fully open, in one-pipe systems N must be used checked 16 November 2026
- Grīvas iela estate 1958–1960, six-storey blocks with studios in the attic; in Iļģuciems series 602 nine-storey and 12-storey Czech-design blocks checked 16 November 2026