That is why a close-up photo of the valve and the head helps in the form. Stopping and fixing a leak costs from €40, labour only; materials are extra.
From €40 for a leak: what is and is not included
- Included: finding where it leaks: the valve stem, the nut or the radiator body.
- Included: replacing the stem seal or gasket and resealing the nut, if it can be reached.
- Included: checking in the hot system that the joint is dry.
- Not included: parts, such as the stem seal set or a new thermostatic head.
- Not included: shutting off and draining the riser, which the building manager does.
- Not included: repairing a seam between sections or replacing the whole radiator.
Dripping under the thermostatic head: the repair step by step
- The head comes off Without the head, the valve stem and its seal are visible. If the stem is wet, the fault is the stem seal; if the nut at the pipe is wet, the fault is the joint.
- The stem seal is replaced without draining the water Danfoss states for its RA-N valves that the whole stem seal unit can be replaced without draining the system. For other models, check the marking on the body.
- The nut is resealed If tightening the nut is not enough, the radiator is shut off with both valves. If there are no valves or they do not hold, the riser has to be shut off, and that is the building manager’s decision.
- Checked in the hot system After the work the head is put back and the joint is inspected once the radiator has warmed up again.
Danfoss RA-N data sheet: the stem seal unit can be replaced without draining the system; the red protective cap must not be used as a shut-off device. Checked 16.11.2026.
The thermostatic head shows 3 and the room is cool
For its K head, the manufacturer IMI Heimeier states that number 3 corresponds to about 20 °C, with about 4 °C between adjacent numbers and about 1 °C between the marks. The manufacturer does not recommend a setting above 4, because each extra degree in a room uses about 6% more energy.
If the head on 3 does not warm the room, first look at what covers it. A head with a built-in sensor must not be covered with a curtain or a radiator cover, fitted vertically or put in a narrow niche: then it measures its own heat, not the room’s. Such a place needs a head with a remote sensor.
Fitting a thermostatic head on an existing valve body does not require draining the water. Installing thermostatic valves does change the valve body, so in a block of flats it is done on a date set by the building manager, when the riser is empty.
The valve whistles or hisses
For quiet operation of Danfoss RA-N valves, the pressure drop across the valve is recommended not to exceed 30–35 kPa; the maximum pressure difference is 0.6 bar. Whistling when the head is almost closed can mean a large pressure difference in the building’s system. It is regulated at the heat substation, so it should be reported to the building manager, not fixed by replacing the valve.
Details of the faulty radiator
- Where it drips: under the head, at the nut, from the body or from a seam between sections.
- The marking on the valve or head (make, model).
- Whether the radiator has valves on both sides.
- The floor, and whether it is a block of flats or a private house.
- A close-up photo and a photo of the whole radiator.
Bleeding radiators before you call
If a radiator is warm only at the bottom and cool at the top, it is not a repair but air. You can usually bleed it yourself; see the advice on bleeding radiators. If in a private house the bottom part stays cold, heating system flushing helps.
A leak and a thermostatic head in one visit: the total
Example: in the kitchen it drips under the head, and in the bedroom the head has to be replaced. Stopping the leak from €40 plus replacing the thermostatic head at the hourly rate from €25/h, if it takes an hour: at least €65 for labour. The stem seal and the head are extra.
Whether the trip is charged separately, the plumber tells you on the call before the work.
Sources
- The RA-N stem seal unit can be replaced without draining the system; the red cap is not a shut-off device checked 16 November 2026
- RA-N: pressure drop for quiet operation up to 30–35 kPa, maximum pressure difference 0.6 bar checked 16 November 2026
- K head: 3 ≈ 20 °C, 4 °C between numbers, 1 °C between marks, above 4 not recommended, 6% per degree; 6–28 °C, frost protection for a cellar, zero position about 0 °C checked 16 November 2026
- A head with a built-in sensor must not be covered, fitted vertically or put in a niche; then a remote sensor is needed checked 16 November 2026