Send the form and we contact you within 5 minutes

Plumber in Zolitūde, Riga - series 104 towers and series 119 blocks

A plumber in Zolitūde works in two very different parts of the neighbourhood.

After you send the form, we contact you within 5 minutes.

Request to a plumber

After you send the form, we contact you within 5 minutes

Your data is secure and will not be shared with third parties

By submitting this form, you agree to our privacy policy

Average response time: 5 minutes

In the north, between Zolitūdes iela and Endzelīna iela, there is a high-rise estate of series 119 blocks, designed in Latvia, and a few series 104 panel blocks of 12–16 floors with a single stairwell. The centre and south of the neighbourhood are dominated by detached houses. In flats the work often concerns risers and days without hot water; in detached houses, the house’s own incoming supply pipe, yard sewer line and water heater.

Four types of building in Zolitūde

Building Where and when The plumbing side
Series 119 high-rise block a high-rise estate in the north of the neighbourhood between Zolitūdes iela and Endzelīna iela heating and hot water from the district networks; a radiator or towel rail is replaced only with approval
Series 104 panel block, 12–16 floors, one stairwell a few blocks in the neighbourhood; the source does not give the year of construction one riser serves the flats one above another on all floors; in an emergency the neighbours are directly above and below
Detached house in the centre and south of the neighbourhood, where detached houses dominate; the oldest appeared in the early 20th century between Zolitūdes iela, Rikšotāju iela, Apūzes iela and Gramzdas iela its own incoming supply pipe and meter chamber, a yard sewer line and often its own water heater
Two-storey multi-flat building the 1930s (20th century), in the same block of streets may have one incoming supply pipe for several flats

Zolitūde covers 288.8 ha, and 16,392 people lived there in 2025. From the centre of Iļģuciems to Zolitūde it is about 4.6 km (our map reading).

A day without hot water and a backup water heater

The Zolitūde residential area is in a zone where there is no hot water during the hydraulic test of the Imanta and Zasulauks heat substation networks. How this day goes is described in the advice article no hot water in the flat. Anyone who needs hot water on that day too hangs a small water heater in the flat, connected to the cold water pipe.

A backup water heater sits switched off for most of the year, and that is its weak point. AS “Rīgas siltums” advises that in buildings with hot water tanks the water be heated periodically above 55 degrees. The manufacturer Ariston uses an anti-legionella cycle in its electronic water heaters: the water is heated to 60 °C and held for one hour, and if the water heater constantly runs below 55 °C, the cycle is repeated every 30 days.

Hot water carries another risk too. Ariston warns that water hotter than 50 °C scalds instantly, and it endangers children and elderly people most. So the manufacturer recommends a thermostatic mixing valve on the hot water outlet of the water heater.

One riser, sixteen floors

In a series 104 tower the riser connects flats that lie directly one above another. If a section is replaced on one floor, the water is shut off for the whole riser, that is, for all the flats on that vertical from bottom to top. So the work is first agreed with the building manager, who also shuts off the riser.

The Residential Property Management Law states that the building’s owner is responsible for managing the building, and in an apartment block the owner is made up of the flat owners. A riser is common property: unless the building’s documents say otherwise, the decision about it is taken jointly, and for details ask your building manager.

For a soil stack, the price of a section includes the transitions to the neighbouring sections above and below. If the neighbour’s section is of a different material, the transition is the most important point of the job. In the form write which floor you live on, how many floors the building has and what material the sections above and below you are made of, if you can see it in the boxed-in riser duct in the toilet.

What costs what in a Zolitūde flat

  • Hanging and connecting a water heater: from €70 for 1 unit, on existing supplies with a safety valve.
  • One water or drain connection point: from €35 per point.
  • Replacing a water riser section: from €110 per riser section on one floor.
  • Replacing a soil stack section: from €100 per riser section on one floor.

Example: a backup water heater in a kitchen where there are no supplies yet, and two connection points (cold water to the water heater, hot water from it) come to from €70 + 2 × from €35 = at least €140. Labour only; materials are extra. Whether the trip is charged separately, the plumber tells you on the call before the work.

Jobs for Zolitūde buildings

For a backup water heater there is water heater installation in Zolitūde, and for a water heater that has stood for a long time water heater descaling. For a section in a tower block, riser replacement suits. A radiator in a series 119 flat is replaced under an agreed project, once the riser is drained, and the dates and permission are set by the building manager: see radiator replacement. When a radiator stays cold at the bottom while its top is warm, bleeding radiators helps. Among the neighbouring neighbourhoods are Imanta and Šampēteris, and Iļģuciems is on our home page.

Sources

  1. Series 119, designed in Latvia, dominates Zolitūde checked 16 November 2026
  2. Series 104 blocks of 12–16 floors with one stairwell in Zolitūde checked 16 November 2026
  3. High-rise estate in the north between Zolitūdes iela and Endzelīna iela; detached houses dominate in the centre and south checked 17 November 2026
  4. Single-family houses in the early 20th century and two-storey multi-flat buildings in the 1930s between Zolitūdes iela, Rikšotāju iela, Apūzes iela and Gramzdas iela checked 16 November 2026
  5. Zolitūde area 288.8 ha, 16,392 residents in 2025 checked 16 November 2026
  6. The Zolitūde residential area is in the test zone of the Imanta and Zasulauks heat substations checked 16 November 2026
  7. Hot water is restored that evening if there are no faults; building managers are informed checked 16 November 2026
  8. In buildings with hot water tanks, heat the water periodically above 55 degrees (Rīgas siltums) checked 16 November 2026
  9. Ariston anti-legionella cycle 60 °C for 1 h, every 30 days; scalds above 50 °C, thermostatic mixing valve checked 16 November 2026
  10. HSE: store at 60 °C, distribute at at least 50 °C checked 16 November 2026
  11. Residential Property Management Law, Section 9 checked 16 November 2026
  12. Ownership boundary; in an apartment block the user’s system is common property checked 16 November 2026
  13. Radiator replacement under an agreed project, with the riser drained (Rīgas siltums) checked 16 November 2026

Prices and rules rechecked 16 November 2026; page text updated 18 November 2026.

Illustration: the stairwell of a nine-storey panel block with an open niche showing water risers with red valves
Illustration: the stairwell of a nine-storey panel block with an open niche showing water risers with red valves

Hanging and connecting a water heater

from €70

1 unit

Book a plumber

Job prices in detail

Labour only; materials are extra. The plumber tells you the total before starting.

Job prices in detail
What is done Cost
Hanging and connecting a water heater 1 unit from €70
One water or drain connection point per point from €35
Replacing a water riser section per riser section on one floor from €110
Replacing a soil stack section per riser section on one floor from €100

Questions residents ask

On the test day the hot water did not come back in the evening. What does that mean?

AS “Rīgas siltums” restores hot water that evening if no faults were found in the test. If the water does not come back, most likely something in the network has to be repaired. Rīgas siltums informs building managers about it, so ask your building manager.

A backup water heater stands switched off from one test to the next. What should I do before I switch it on?

AS “Rīgas siltums” advises running rarely used taps for a few minutes at least once a week. You can do the same with the hot tap on the water heater. The British HSE advises keeping hot water in the tank at a minimum of 60 °C, and at the tap it should reach at least 50 °C. If the water heater has stood for a long time and the water smells, see water heater descaling.

In a two-storey house there is one water supply for several flats. Who replaces the pipe to the house?

Under the Law on Water Management Services, the supplier’s network and the user’s system meet at the ownership boundary, which in an apartment block is the flat owners' common property. So usually all the owners replace the pipe from the boundary to the house together. How this is divided in your building, ask your building manager.

Send the job to a plumber

Scroll up to the form at the top; once you send it, we contact you within 5 minutes.

Open the request form
Book a plumber we contact you within 5 minutes